INEX 2026

Innovation Catalogue

FROM DRIP TO DROP: A Buoyancy-Based Automatic Blood Backflow Prevention Device for Intravenous Administration

Industry 4.0

From Drip to Drop is an innovative, buoyancy-based device designed to prevent blood backflow during intravenous administration. It incorporates a hollow spherical floating mechanism that moves with the falling fluid level and is designed to engage the outlet valve seat when the fluid reaches a critical level. This passive mechanism aims to reduce reverse blood flow, improve IV safety and minimize the need for continuous manual monitoring.

Innovator(s)
Jinnikuntla Santhosha, P. Naga Haritha
Organisation
St. Pauls College of Pharmacy
Country
India
Exhibition zone
Product Arena
Technology Readiness Level
TRL 3 of 9
Edition
INEX 2026

About this innovation

FROM DRIP TO DROP: A Buoyancy-Based Automatic Blood Backflow Prevention Device

Introduction

Intravenous (IV) administration is one of the most commonly used methods for delivering fluids and medications in healthcare settings. However, when the infusion fluid level becomes critically low or the saline container empties, blood may flow backward into the IV tubing. This can contribute to blood stagnation, clot formation, tube blockage, blood leakage and additional workload for healthcare professionals.

Proposed Innovation

From Drip to Drop is a novel, passive buoyancy-based mechanism designed to prevent blood backflow during intravenous administration. The device incorporates a specially designed hollow spherical float positioned within a transparent chamber assembly.

Working Principle

The hollow spherical float remains buoyant while sufficient IV fluid is present. As the fluid level decreases, the float gradually descends within its guide cage. When the fluid reaches a predefined critical level, the float is designed to engage with the valve seat near the outlet aperture, restricting reverse flow through the IV system.

Major Components

  1. Top inlet cap

  2. Top gasket

  3. Transparent chamber sleeve

  4. Upper float retainer

  5. Hollow spherical float

  6. Guide cage

  7. Valve seat ring

  8. Lower gasket

  9. Bottom funnel/outlet cap

Unique Selling Proposition (USP)

  • Passive buoyancy-based operating mechanism.

  • No electronic power or external energy required.

  • Automatic fluid-level-responsive movement.

  • Compact and transparent component assembly.

  • Designed for integration with conventional IV systems.

  • Potentially affordable and scalable design.

Objectives

  • Develop a mechanism to reduce blood backflow during IV administration.

  • Minimize unnecessary blood leakage and tubing-related complications.

  • Reduce dependence on continuous manual observation.

  • Improve patient safety and healthcare workflow.

  • Develop a cost-effective and practical IV safety solution.

Potential Applications

  • Hospital wards

  • Emergency departments

  • Intensive care units

  • Infusion centres

  • Government hospitals

  • Resource-limited healthcare facilities

Development Status

The innovation is reported at Technology Readiness Level (TRL) 3, with preliminary analytical and design validation completed. Development of a working prototype and controlled simulated-use testing are the next steps.

Future Scope

Future development will focus on prototype fabrication, leakage and flow testing, backflow challenge testing, material biocompatibility assessment, usability evaluation and applicable regulatory requirements.

Expected Impact

From Drip to Drop aims to provide a simple, passive and potentially cost-effective approach to improving IV administration safety while reducing the monitoring burden on healthcare professionals.